Areas of application
- For indoor and outdoor use.
- Load-transferring, supporting, force-transmitting bond between concrete foundations and machines, steel bed plates, steel rails (crane track rails) and high shelving pillars.
- Precise grouting of machines, turbines, pumps and generators.
- Force-transmitting grouting of pre-fabricated concrete pillars in hole footings.
- Void-free bond between components and non-reinforced concrete or reinforced concrete.
- For grouting heights from 5 to 100 mm.
Product features
- Meets the requirements of DAfStb guideline (VeBMR, German Commission for Reinforced Concrete) "Production and application of cementitious performance concrete and performance grout"
Flowability class | f3 |
Shrinkage class | SKVM I |
Early strength class | A (≥ 40 N/mm 2 after 24 hours) |
Compressive strength class | C 60/75 |
Exposure class to EN 206 | XO, XC4, XD3, XS3, XF3, XA2 |
- Helps produce a smooth bond free of cracks and cavities, enabling calm machine running and therefore more accurate working and lower wear and tear of machinery.
- High early and final strength.
- Self-leveling properties for easy filling of horizontal cavities.
- Pumpable, in open system with separate mixer and supply pump.
- Shrink compensated, crack-free curing of the grout, accurate to dimension and maintaining the volume.
- Resistant to frost and de-icing salt.
- Suitable for exposure classes X0, XC1-4 and XF1-4 as described in EN 206.
- Force-locked, supporting bond, provides for a homogeneous load transfer to the foundation.
- Chloride free, does not cause corrosion to steel.
- Sulfate resistant.
- Water impermeable.
- Certified to EN 1504-6.
- Certified to EN 1504-3 class R4.
Colors:
grey
Forms of delivery:
25-kg-bag
Consumption calculator
Your Result
Quantity Required approximately
kg
corresponds
25-kg-bag
pieces
This consumption calculation included in the program contains approximate values based on experiences which might considerably vary upwards and also downwards depending on the structure of substrate, type of tiles, different profiles on the reverse sides, type of tiling tools, work method a.o. Calculations are therefore not allowed to be based on these values. In case of larger projects we recommend to assess the consumption by making a trial surface. Applications in the combined method (buttering-floating) increase the consumption by approx. 20 to 25%. In case of powder products the data relate to the consumption of dry powder for easier calculation of the material requirement.
YOUR DIRECT CONTACT
Downloads
Technical data sheet
Safety data sheet
Declaration of performance EN 1504-6
Declaration of performance EN 1504-3 (R4)